Not known Details About Dp50rb
Not known Details About Dp50rb
Blog Article
Guidance 4D probe; acknowledge the probe by way of the ID code; change the 4D push sign via the electrical relay to generate the 4D probe do the job Usually. four.2.2 Major board The leading board might be divided into two areas: entrance-finish of the primary board and back-conclude of the leading board.
The user is not really permitted to open the handles and panel from the program, neither Take note: machine disassemble is allowed. To make sure the procedure effectiveness and safety, only Mindray engineers or engineers approved by Mindray can carry out upkeep.
Get a complete and extended check out on the anatomical structure by way of panoramic imaging coupled with velocity sign and ahead/backward scan skill creating scanning easier, smoother plus more controllable.
Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.
By continuing your stop by on our Site, you are consenting to our use of cookies. Having said that, you can improve your cookie options at any time. Cookie choice Accept and Continue
Written content Method Verify the battery periodically : a) Verify if battery can be charged Ordinarily when ability-on: That the current ability is 100% or ability will increase soon after a brief time indicates which the battery is usually charged normally.
Site one hundred forty five Clear control panel Tools: dry comfortable cloth, gentle soapy drinking water Process: Use dry gentle cloth to clean the surface on the process. When the method is dirty, moisten the delicate cloth with moderate soapy h2o and wipe off any stains. Use dry tender fabric to eliminate any moisture and allow all challenging surfaces to wholly air-dry. Web page 146: Clean The Peripherals
Explore improved diagnostic data as a result of prolonged view from the anatomical structure on all convex probes.
Evaluating sufferers in nowadays’s demanding atmosphere involves revolutionary technology that enables clinicians to help make fast and self-confident diagnoses. The versatility with the DP-50 expands your clinical utility even though assisting to make improvements to patient care.
Function: Around the again-end of the key board, a Particular check IC is applied to observe signal voltages and clock battery power which are supplied to the primary board by the primary device box electric power provide module.
The DP-50 Professional is surely an progressive, high-overall performance Ultrasound System engineered to help you obtain the insights you may need. The Program’s effective motor and higher-pace Dp50rb processing offer superb picture quality and a complete details administration solution.
Find out superior diagnostic information and facts by means of extended see in the anatomical construction on all linear probes
NOTE: In advance of inserting the connector into the probe port, inspect the connector pin. If your pin is bent, don't use the probe right up until it's been inspected / fixed / replaced. Installing Peripherals To the types in the supported peripherals, make sure you consult with “two.
Your Device for deeper biopsy: allowing for changes to your scan line to realize greater visibility from the needle, nerves and modest vessels, guaranteeing the continuity of all info.
Observe: Be sure that you could potentially pull out and drive in the IO board sockets vertically when pulling out and assembling the IO board assembly around the placement of your deal with. Remove panhead screws with washers M3X6 (4) utilized to secure the IO board, after which you can take out the IO board. Site 116 Get rid of panhead screws with washers (two M3X6) that happen to be fastened on the key device, just take out the higher baffle then pull out two cables connecting the primary board to the facility module assembly.