one.two.two Warning Labels Warning Labels That means Be sure to very carefully look at this guide in advance of use device. The following labels can be a. Tend not to area the product over a sloped surface area. Normally the readily available in the event the process machine may perhaps slide, leading to particular harm or perhaps the system works with the cellular malfunction.

The consumer is not really permitted to open the covers and panel of your technique, neither Notice: product disassemble is permitted. To make sure the procedure efficiency and basic safety, only Mindray engineers or engineers licensed by Mindray can execute servicing.

Get a complete and prolonged check out with the anatomical framework through panoramic imaging coupled with velocity indication and ahead/backward scan skill creating scanning much simpler, smoother plus much more controllable.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

Click on Concur and Move forward to accept cookies and go directly to the website or click on More info to view thorough descriptions of the kinds of cookies and decide on no matter whether to accept selected cookies although on the location.

Mindray’s new generation of black & white ultrasound procedure, DP-fifty Professional, is supplied with Sophisticated imaging technologies enabling further penetration and faster impression acquisition with higher resolution.

Website page a hundred forty five Thoroughly clean control panel Instruments: dry soft cloth, mild soapy water  Approach:  Use dry tender fabric to scrub the area of the program. If the method is dirty, moisten the delicate cloth with mild soapy water and wipe off any stains. Use dry gentle fabric to eliminate any dampness and allow all challenging surfaces to absolutely air-dry. Site 146: Clean up The Peripherals

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi depth mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

iZoom™ allows precise viewing of graphic from length iWorks™ Protocol will help standardize workflow and cut down exam instances

5.two.3 Geometric positioning precision Longitudinal geometric positioning accuracy  Check Stage: Do changes as the way in tests the maximum depth. Document the space by 20mm Just about every segment around the longitudinal targets line utilizing the measurement caliper; Pick the worth with the greatest mistake (to 20mm), compute the precision using the components underneath The measurement caliper must be positioned on the higher edge of the focus on, Be aware:... Web site seventy nine Transverse geometric positioning accuracy  Examination Step: Address the scan surface area of the phantom with drinking water or pair gel, gently Speak to the probe Together with the scan surface area Adjust the depth, generating the transverse targets to generally be displayed inside the picture. Change the main target stage to get posited beside the transverse targets (the conventional isn't crystal clear) Regulate parameters like gain, TGC, making Every transverse targets to get Plainly exhibited. Web site eighty 5.5.two.four Blackout Location Examination Step: Cover the scan surface of your phantom with drinking water or pair gel, gently Call the probe Using the scan floor Adjust the depth at a lessen worth, and set the main focus at the closest place to the scan surface area. Lessen the worth of parameters like AP, Acquire right until the background noise just is often noticed. Site eighty one: Computer software Enhance And Routine maintenance

Soon after successful link, the recently extra community printer identify will probably be proven from the printer driver record. NOTE: Ahead of hook up the community printer, be certain the ultrasound method plus the printer are in a similar community area, plus the network is Performing Commonly. The IP tackle plus the server title needs to be valid, e.g. Web page forty seven DICOM Placing  Enter the AE Title with the ultrasound process, port and PDU based on the true problem, after which you can click on [Okay] to exit the monitor.

.. Page 161 The indicator on the printer Errors come about once the adapter turns orange, and also the printing printer adapter operates. Disconnect and connect the fails. ability adapter, electric power within the printer adapter again, and confirm whether the printing is standard soon after one minute. Website page 163: Electrical Security Inspection

Functionality Check 5.five.1 Test Procedure Resolution Detection depth Geometric Place Precision Blackout space exam Report the Examination photographs 5.five.two Take a look at Information The picture employed Here's only for reference, stick with the graphic influence in the real Take note: problem. Prerequisites: Display screen: set the distinction and brightness with the clinical application benefit (or even the default position) Operation natural environment: dark place, simulating the clinical application natural environment. Webpage seventy six In situation the transverse resolution tests targets are horizontally displayed, report the minimum distance of two targets that can be Obviously identified. Repeat the Procedure above to the transverse resolution screening targets at other depths. As revealed in determine below. Axial resolution ... Webpage 77 When using the convex probe, retain the transverse resolution tests targets to notice: be shown near the midline. When using a linear probe with steer operate, will not activate the steer functionality when carry out the transverse resolution check. Zoom from the area wherever the targets Found if essential. The diameter in the goal position at a certain depth is equivalent on the Dp50rb login transverse resolution on the depth. Web page seventy eight 5.

Mindray respects your privateness. We use cookies for various needs, for example Web site features, increasing your encounter of our Web site, building integration with social websites and aiding focus on our advertising and marketing.

Be aware: Be certain that you might pull out and force into the IO board sockets vertically when pulling out and assembling the IO board assembly within the situation of the manage. Take away panhead screws with washers M3X6 (4) utilized to safe the IO board, and then you can choose out the IO board. Site 116 Take away panhead screws with washers (2 M3X6) that are fixed on the primary device, consider out the higher baffle then pull out two cables connecting the leading board to the facility module assembly.